How to stop continuous transmission of EPIRB? CLICK HERE TO DOWNLOAD


EPIRB FALSE ALERT CANCELLATION

How to stop continuous transmission of EPIRB?

If manually activated:
Pull back the switch to OFF position, put the locking pin

If automatically activated:
Wipe out the sea water contact screw with cotton cloth
(Dry the sea water contact screw)

If EPIRB can not be retrieved:
EPIRB will stop transmission after 48 hours
we can inform RCC



you have retrieved EPIRB. But you can not stop the continuous transmission
of EPIRB. What will you do?
Remove the battery.
EPIRB has two halves. Upper half and lower half. Unscrew the joining screws.
Battery in the lower half.
OR
Fully cover EPIRB with an aluminium tin foil sheet. No transmission will be sent out from the aluminium tin foil cover (Protection)

EPIRB FALSE ALERT CANCELLATION through TEERESTRIAL communication
In SEA AREA A4:
CONTACT CRS on HF or MF (depends on the distance)
On voice – MF or HF
Give the cancellation message to CRS and request them to forward the cancellation message to RCC
RCC phone numbers are available in the ALRS VOLUME 5 – SAR pages
(If you can contact RCC through terrestrial, you can convey the cancellation message)
(Example: VLADIVOSTAK/MURMANSK –RUSSIA)